Skip to main content

Motor and Mep

12th April

Pratishtha Bhawan

Motor
Rtflex fuel injection (full xplain , from fuel p/p to injector)
Rtflex advantages
Tribo pack technology
Boiler safety v/v type onboard , different types of safety v/v and difference between high lift and improved high lift
Thin shell bearing (explain full)
Types of sewage treatment plants?

Mep
Stuffing box purpose? How will u know if it performing okay? Then said explain full construction. Can we remove stuffing box with piston in place? If yes , how?
Aux engine main bearing dismantling procedure.
Radial clearance explain and how to take..if more what it signifies?
Crankpin ovality . How to check? Limits? What to do if ovality found?
Liner calibration. How to check ? Ovality  limits?

Decider
Aux engine crankcase inspection ( liner me kya kya check kroge)
Why we do boiler water tests onboard? How will chloride increase?

Result -- COC😍

Comments

Popular posts from this blog

Wire drawing effect

Wire drawing effect : It is erosion or scoring of valve seat and disc material of the valve . Causes : 1. Due to differential pressure across the valve . 2. Thermal and mechanical damages . Effects : Valve is unable to isolate the line and fails in sealing . Gas and liquid will leak from the wire and scratch like groove .

Difference between Attemperator and De-superheater

Attemperator are fitted in order to keep the steam temperature in the final stages of the superheater within certain desired limits . This is done for two main reasons . 1. The most important is the protection of the superheater tube material from the effects of overheating. *Mild steel superheater tubes tubes should not be subjected to steam temperatures in excess of 455℃. 2. The formation of bonded deposits on superheater tubes can be reduced if steam and gas streams within certain temperature ranges are prevented from coming into contact of each other. De-Superheater is used to reduce the temperature of a quantity of superheated steam and make it suitable for used in auxiliary services requires low temperature or saturated steam . *The reason for doing this way rather than by taking the saturated steam direct from steam drum , is to protect the superheater , these must be protected against overheating under all conditions of load by circulating steam through them . *Al...