1. Rolling , pitching and yawing etc. movement of the ship .
2. Leakage from jacket cooling water or from piston cooling water .
3. Storage tank valve kept opened .
4. Wrong operation of the purifier .
5. Transfer pump wrongly lined up .
Source : Deven Aranha