1. Change the gravity disc of correct size which is smaller for diesel .
2. Heater bypass valve should open .
3. Close the steam inlet and outlet valve to the heater .
4. Drain the heater.
1. Open up the purifier and place the blind disc at the bottom of disc stack. 2. The water outlet is blocked by seal on the gravity disc. 3. Blank off sealing water inlet line .