operating water solenoid valve not function

Operating water solenoid valve malfunctioning. Causes and remedy 1. Control unit is defective. Action:  contactact service backup support.  2. Wire break in the connecting terminal.  Action: Replace wire.  3. Connecting terminal on the connector block is loose. Action: tighten the screw of terminal. 4. Coupler socket loose. Action l: tighten coupler socket.  5. Magnetic coil defective. Action: Replace the solenoid head.  6. Diaphragm defective.  Action: Replace diaphragm. 

centrifuge disc stacks functions

Centrifuge Disc stacks functions  1. Splits the liquid mixture consisted of a light phase and heavy phase ,  e.g. oil-water,  into its components. 2. Each disk is provided with spacers so that precisely defined interspaces are formed between the individual disks to facilitate sliding of the solids and self -cleaning of the disks.